Refrigerant Charging Hoses Set of 3

Category: Refrigeration AccessoriesSupplied from Industrial Area, Nairobi

Every AC or refrigeration service starts with a good connection. Old, cracked or leaking hoses let air and moisture in and waste gas. They can also give false gauge readings. Refrigerant charging hoses connect your manifold gauges to…

  • Colour-coded set.
  • Holds high pressure.
  • Leak-tight seals.
  • Standard 1/4 inch SAE fittings.
  • Flexible and easy to handle.

Prices on request. We confirm stock, price and delivery when you get in touch.

In stock

  • Same-day deliveryOn confirmed orders, subject to stock
  • Genuine productsTrusted brands for industry
  • Technical adviceHelp choosing the right part
  • Industrial Area, NairobiDar es Salaam Road, off Enterprise Road

Refrigerant Charging Hoses for AC and Refrigeration Work

Every AC or refrigeration service starts with a good connection. Old, cracked or leaking hoses let air and moisture in and waste gas. They can also give false gauge readings. Refrigerant charging hoses connect your manifold gauges to the system, the gas cylinder and the vacuum pump. They’re built to hold high pressure without leaking. At Wisdo Merchants, we supply refrigerant charging hoses to AC technicians, fridge repairers and refrigeration contractors across Nairobi and Kenya.

A standard set has three colour-coded hoses. The blue hose connects to the low-pressure side and the red hose to the high-pressure side. The yellow hose goes to the gas cylinder or the vacuum pump. Each end has a knurled nut with a rubber seal, and the end that fits on the system pushes down the Schrader valve core in the service port. As a result, the hoses seal tightly and let gas flow only when connected.

Features and Benefits of the Refrigerant Charging Hoses

  • Colour-coded set. Blue, red and yellow hoses make it easy to connect the right side every time.
  • Holds high pressure. Reinforced hoses are made for the working pressures of common refrigerants.
  • Leak-tight seals. Rubber gaskets in each nut seal against the port without overtightening.
  • Standard 1/4 inch SAE fittings. They fit most manifold gauges, service ports, cylinders and vacuum pumps.
  • Flexible and easy to handle. Hoses reach comfortably between the unit, the gauges and the cylinder.

For technicians, this means faster, cleaner connections and accurate readings. Meanwhile, contractors waste less refrigerant on every job.

Technical Specifications

PropertyValue
ProductRefrigerant charging hoses
Set3 hoses: blue (low side), red (high side), yellow (service)
Fittings1/4 inch SAE flare nuts with rubber seals
Port endSchrader core depressor
ConstructionReinforced, high-pressure hose
RefrigerantsCommon HVAC refrigerants such as R134a, R22, R404A and R32
UsesCharging, evacuation, recovery and pressure testing

Applications of the Refrigerant Charging Hoses and How to Use It

  • Charging split, ducted and window AC units
  • Servicing fridges, freezers and cold rooms
  • Evacuating systems with a vacuum pump
  • Recovering refrigerant before repairs
  • Pressure testing with nitrogen

Connecting the Hoses for a Recharge

Picture a technician recharging a split AC after a repair. First, they connect the blue hose from the manifold’s low side to the suction service port, and the red hose to the high side if there is a port. Next, they connect the yellow hose to the vacuum pump and pull a deep vacuum. After that, they move the yellow hose to the gas cylinder and purge air from it by loosening the nut slightly at the manifold. Finally, they charge the system and close the valves before removing each hose quickly to keep gas loss low.

Completing Your Service Kit

Connect the hoses to our two-gauge refrigeration manifold, and evacuate with our two-stage evacuation pump. For almost no gas loss when you disconnect, fit our blue and red port safety valves. For other tools, browse our refrigeration accessories.

Safety and Handling

  • Wear gloves and goggles. Liquid refrigerant can cause frostbite and eye injury.
  • Check the seals. Replace missing or cracked rubber gaskets before use.
  • Never exceed the hose rating. Check the pressure rating, especially for high-pressure gases such as R410A.
  • Purge air before charging. Air in the hoses contaminates the system.
  • Store them coiled and capped. Keep dust and moisture out, and don’t kink the hoses.

Frequently Asked Questions

What do the blue, red and yellow hoses do?

Blue connects to the low-pressure side and red to the high-pressure side. Yellow goes to the gas cylinder, recovery machine or vacuum pump.

Can I use these hoses on R410A?

R410A works at higher pressures and uses 5/16 inch service ports. Ask our team for hoses and adapters rated for R410A.

How often should I replace charging hoses?

Replace them if they crack, bulge or leak, or if the seals wear out. Check them before every job.

Why do my hoses leak at the nut?

The rubber seal inside the nut is usually worn or missing. Replace the seal and tighten by hand.

Do you deliver outside Nairobi?

We offer same-day delivery once your order is confirmed, subject to stock availability. Call or email our sales team to confirm stock and arrange delivery to your site.

Order Refrigerant Charging Hoses from Wisdo Merchants

Good hoses give clean connections, accurate readings and less wasted gas. Our refrigerant charging hoses keep every service job running smoothly. Furthermore, you can browse our refrigeration accessories to complete your kit.

Visit us: Dar es Salaam Road, Off Enterprise Road, Industrial Area, Nairobi
Call: +254 795 938305
Email: sales@wisdomerchants.com

Reviews

There are no reviews yet.

Be the first to review “Refrigerant Charging Hoses Set of 3”

Your email address will not be published. Required fields are marked *